Based on the many presentations we have provided over the years on this topic, there are some common themes and questions. While many of these were addressed in later iterations of the presentations, they are grouped and listed here – you can click on a question to make the answer visible or hide it again. Please note that while every property is different the answers are often kept quite generic. If you would like advice specific to your property, then get in touch.

Please note that the information provided here is presented for guidance only. Regulations, standards, products and government policy can change, and information that was relevant at the time of publication may no longer be current when you read it. Please keep this in mind before applying any information or suggested approach to your own situation.

The questions are grouped by topic – use the links below to jump to the section most relevant to your problem:

Building Fabric

Damp and Mould
Q - My house has solid walls and exterior insulation applied, which is polystyrene and cement render over the top. Can you explain our ongoing black mould problem inside? Is it damp (damp monitoring did not find that the walls with mould on were damp) ? There were problems prior to us moving into the property and those were resolved, but we are now many years later and we have problems again.

Answer - As a question this demonstrates that often one must consider and identify the factors that may be causing such problems. The first question lies around how the damp problem was addressed/dealt with in the past? The reason why this is important is because in many cases the solution to damp problems does not address the source of the problems, but it looks at the effect and aims to deal with those. This means that in many cases what happens is that they, for example, plaster a wall with a material that is not breathable, and so that material would then not let the water through – this then also means that the water remains within the wall, even if it may not become clear to the inhabitants. In this case, it turned out that the inside of all external walls had been plastered with a non-breathable material. This then led to aiming to understand if the outside of the wall could still breath. It turned out that the wall had external insulation added, of the non-breathable type and then there was render added. In this case it does not even matter if the render is breathable at all, as the original wall – which was wet in the past and is therefore most likely still wet – is no longer able to get rid of that moisture on the inside (due to plaster) or the outside (due to insulation). The moisture problem as it appeared now was apparently also on a single wall, which was the party wall – this was a wall that had not been treated in the past (because it was not an external wall and not wet). Now why does this wall cause a problem now? That is because the external walls are wet and that moisture builds up in those walls (as they cannot get rid of it) and so this moisture travels through the wall and has now built up to such an extent that it has reached the party wall, where the inside is still breathable, hence the moisture is becoming visible/apparent there. The moisture may then become visible where conditions allow it to accumulate or emerge. Now, how do you solve this problem? The general principle is to understand why moisture is present and how it is moving through the building before deciding how to intervene. For the example described, restoring the wall's ability to manage moisture would be an important consideration, but the appropriate solution for an individual property would depend on its construction, history and current condition.

Q - I live in a top floor flat in a building from 1901 and we have damp and peeling paint persistently inside (in the bathroom). The end outer wall has exterior cement render. How can we find a way to reduce the damp problem inside ?

Answer - Ideally you need to work on getting that wall to be able to breath a bit more. The outside is clearly not breathable (cement render) and the inside will have tiles in areas (which is also not allowing moisture through) and then the areas which you painted. We would recommend you ensure that the paint you use is breathable, not all paints are (which can be related to them peeling off). This also means that you may have to remove all old paints before you apply new ones though. Natural paints, like clay paint etc, are all breathable. They are also the paints you would use on top of a lime plaster. The other thing to think about is ensuring there is sufficient ventilation within the property and taking that you are in an apartment building, we would recommend that you look at a ventilation system along the lines of a decentralised MVHR – this allows you to install individual ventilation units at different points within the property, while they all work together to ensure proper ventilation to the property. The benefit of these units over a standard fan is that they also do heat recovery. Please do consider how such a ventilation system will operate in the light of airtightness and that if you have trickle vents that this may not be suitable at all, in which case a good ventilation in the bathroom only may be your better option – and may even be the best option as a starting point.

Q - My property has cavity wall insulation that has been sprayed in/added after the property was built. We have condensation/damp problems within the property, what should we do ?

Answer - One of the problems with adding cavity wall insulation afterwards is that you make a direct connection between the inside and outside wall, and this could allow moisture/water to travel from the outside wall to the inside wall (and vice versa). However, there is also the possibility that the material that has been sprayed is disintegrating and is becoming a liquid (this would not be unusual), and so the best thing to do is to take out a brick (preferably towards the bottom of the wall) and look into the cavity to see what is happening – is the insulation still intact and/or is it disintegrating? In case of the latter, then it is likely that this is causing the dampness on your walls, although before undertaking any physical work it is essential to inspect the specific wall construction and condition. In general, we would recommend that you consider insulation externally or internally (cavity wall insulation added afterwards does not have a good reputation of being “without problems”). If the insulation is still intact, then you will have to identify the type of material used to understand if it is breathable or not.

 

Insulation
Q - For thickness of wall insulation, is it the case that more is better? Is there a point where more insulation is not more efficient, i.e., 800mm vs 1000mm ?

Answer - Normally more is better, but there are limitations. These depend on how the wall is built up (cavity wall, timber frame, … ), current insulation standards (where is the insulation and what material is it: cork, hemp, PUR board) and where you are planning to install the new insulation (inside or outside). If you have a wall constructed predominantly from moisture-permeable materials, then the moisture behaviour of the wall may be easier to manage, although the complete build-up still needs to be considered. The best way of explaining what the challenge is, is if you consider the inside of your property to be at, for example, 21 degrees while it is 0 degrees outside. This means that if one was to “cut through” the wall you would have a temperature profile going from 0 (the outside part of the wall) to 21 (the inside part) – now depending on the materials used (different materials have different thermal conductivity, so for example metal will conduct heat more easily than wood), and their breathability, there will be a point on that “cut through” where your water damp becomes a water droplet. If you consider the case of a cavity wall, then if that water droplet forms within the cavity, then you are fine, as that will ventilate and dry out. If that water droplet is formed closer to the inside of your property, then you may be building up moisture in that wall, which could then lead to growing mould among other problems. If you add insulation to either the inside or outside of the wall, then you move the point within that wall where the water droplet would form, and you would not want that to be inside of your property or affecting the internal spaces – things get a bit trickier if there is a mixture of breathable and non-breathable materials. In short, the key is that any good company should be able to perform the calculations on how much insulation you can get installed – they should consider the thickness of each of the materials (and their type of course) of your existing build up and then also what you would add and where. It is worth asking for those calculations – they often also show the U-value of the full wall structure. Another thing to keep in mind is that if you have a fully breathable wall (from a materials perspective) then make sure that you do not add non-breathable materials on either inside and/or outside. If you already have non-breathable materials then it is trickier, but often less problematic – adding breathable materials then is not normally a problem but you may have to ensure that you do not add too much to the inside as that would bring your damp point to close to the inside of the property. So breathable materials are the safer way to go, but it depends on what you already have as to how much you can install.

Q - Is it feasible to insulate a warm loft by lifting tiles if you’re not having the roof replaced ?

Answer - Yes, you can always take off the tiles, and then insulate and put them back, but the real question is whether that is cost-effective (labour costs over gain). If you currently do not have insulation between the rafters then it may make more sense, but not if there is already insulation there, and it is still performing well. If you want to add more then you will need to consider the timber structure and insulation that are added, which will also bring weight and so you need to have a structure check done that your current rafters can support the additional weight – before you go and take off the tiles and start the actual installation.

Q - Can you get secondary double glazing for sash windows that doesn’t look terrible ?

Answer - The answer depends on what you consider acceptable visually, as this varies considerably across people. Let’s say there are many different options out there, some are possibly more stylish than others, and some will have a better impact (from an efficiency perspective) than others. Often one makes a compromise by choosing to go either way, but there should be several options out there, hopefully some of those are considered “looking fine”.

Q - Is it possible to insulate a cement floor that always feels cold ?

Answer - Cement/concrete is a material that will always feel cold unfortunately. If the aim is to simply make sure that you get rid of that cold feeling when you touch, then a very thin layer of cork, for example, would help. The reason we recommend cork for this is because it is a material that always feels warm and so a thin layer, e.g. 3mm, can already achieve that warm feeling effect. You can buy rolls of cork (1m wide normally) with thicknesses of 2-10mm, which can easily be spread across a floor and that could be used as an underlay for your floor.

Q - My property was built in the 1960’s and has insulation in between the rafters (floor level) of the attic and then boards on top. Can I add insulation boards on top of that ?

Answer - The answer is yes, but the question is whether you use that loft/attic for storage, and if so, then you will need to ensure that the boards do not get compressed by the items you store on them, so you probably need to add wood beams and a next layer of boarding, which then means you are probably better off putting down rolls of insulation rather than boards. The question then also becomes if it is not better to take up the previous boarding as well.
As it turned out the insulation previously installed is fibre glass insulation and the insulation value of that as a material deteriorates over time, and that is further sped up with the addition of dust and moisture. Assuming this insulation dates back to the 60’s, its value is as good as non-existing, so you are better off replacing this as a starting point and then seeing what you build up from there.

Q - I am thinking about underfloor heating in my bungalow that has concrete floors, but I’ve been given conflicting advice about whether I need insulation. I’m worried that insulation will increase the height of the floor.

Answer - Part of the challenge with under floor heating is that you are heating up a large mass, i.e., the floor as such. The larger the mass you need to heat up, the larger the amount of energy that you need to achieve that. As soon as you insulate, you hopefully reduce having to heat up that mass. Considering that concrete is a material that is energy demanding to heat up, then you can understand that insulation will only come in as beneficial. It is not essential, but it would certainly be beneficial, and yes that will come at a higher cost, but if you consider the impact of not installing and that this will be a yearly cost impacting your energy bills then from a cost benefit analysis the installation of (as much as possible) insulation will pay itself back quite quickly.

 

Building Materials

Understanding Materials
Q - Is there a way to tell what kind of plaster has been used in a room ?

Answer - This is not that straight forward, as colour and behaviour under mechanical stress (knocking on the plaster for example) are hard to use as means of identification. In some cases, the setting/context will help, and/or if you have expertise of working with the materials they may be able to tell. One guide that can help is that if you have lime, then the powder will react more extensively (as in creating bubbles) when you bring it into contact with other materials. The challenge with this approach is that if you have not gotten a reference point that it may be challenging to identify what level of activity you should be looking for, but if you go on the web, you can find some videos around this topic.

 

Heating / Cooling - Electrical

Boilers - Hydrogen
Q - I understand hydrogen can be leaky ? Will it be able to be used in our boilers ?

Answer - Hydrogen is a gas and pipework for gas needs to ensure being tight and that needs to be tested accordingly (you can easily buy testing fluid to test for that at a DIY store). It is also worth remembering that these systems are pressurised, so they are under a higher pressure than the surrounding, which would imply that if they are not well sealed, they will leak. Taking that hydrogen has different physical properties from natural gas, its behaviour in existing pipes, joints, seals and appliances needs to be considered separately. The implications therefore depend on the hydrogen concentration and the specific infrastructure involved. The UK has been investigating the potential to blend hydrogen into the existing gas network, including proposals for blends of up to 20% hydrogen by volume in gas distribution networks. However, this remains subject to ongoing technical, safety, regulatory and policy decisions, and there is currently no confirmed timetable for a transition to 100% hydrogen in the domestic gas network. Appliances designed for natural gas cannot simply be assumed to be suitable for 100% hydrogen. Any future transition to hydrogen would require appropriate appliances and supporting infrastructure, and the requirements would depend on the eventual policy and technical approach.

 

Heat Pumps
Q - What are the risks of Legionella from heat pumps ?

Answer - The key distinction is between the closed heating circuit and the domestic hot-water system. The water circulating through a heat pump and heating system is normally a closed circuit and is not the main concern when considering Legionella exposure. The relevant risk is associated with domestic hot water, particularly where water is stored and can remain at temperatures that allow Legionella to multiply. Heat pumps can produce domestic hot water at temperatures suitable for controlling Legionella, but their normal operating temperatures and control strategies vary. Where hot water is stored, the system should be designed and operated in accordance with appropriate guidance for controlling Legionella risk. As a general principle, HSE guidance recommends storing hot water at 60°C or above, with the distribution system reaching at least 50°C within one minute at outlets, while managing the risk of scalding. The optimal temperature range for legionella growth is between 20-25 °C and about 50 °C. Above that then the growth slows down, and they do not survive temperatures above 60 °C. Please note that the main route of exposure is inhalation of contaminated water droplets or aerosols, for example from showers or other outlets that generate fine droplets.

 

Choice of Fuel
Q - What is a better option for cookers? Gas or electricity ?

Answer - We guess that this relates to the sustainable aspect of it all, and that is hard to say really. Gas is more direct in the sense that combustion produces heat at the point of use. If your electricity is not green and comes from a gas power station, for example, then there are many losses along the way before it reaches your home, and that means that there will be more carbon produced for the same heating output. However, if you have your own solar PV panels then you could cook electrically from the output of your panels.

 

Underfloor Heating
Q - You mentioned that underfloor heating could be put into walls. Would you recommend this for exterior or interior walls ?

Answer - It should be noted that there may be minor differences in the system being used for floors and walls, but from an installation perspective, a useful starting point is to focus on internal walls from the perspective that any heat that does not get into one room will benefit another room. As with floor heating consider insulation, as the aim is about ensuring that the heat mainly goes into the room to which it is installed.

 

Ventilation and Cooling
Q - One of the rooms in my property gets really warm in the summer. It is directly facing south and has a rather large amount of glass and heats up so much that I cannot use the room during the summer. I was thinking of adding a solar shade, any recommendations ?

Answer - There are a few options here, you can go for a more solid permanently fixed solar shade. You could opt to install one that can be retracted. Now some other options to think about are the use of a more specialised type of covering for your windows. Effectively the cloth consists of extremely tiny mirrors (easiest way to explain). The benefit is that it lets through the light, and it bounces back the “heat”, and you could mount that on the outside of your windows for the summer. The other option is to look at replacing the glazing, and then we would recommend that you choose a 70/35 type glazing (or better), as this has special coatings that reduce solar heat gain while still allowing a good amount of visible light through. This is more expensive than the currently more standard Low-E, but it has benefits towards heating up from the sun as well as it will reduce heat loss during the winter, so it will not only improve your situation within the season within which you have the main problem, but across the year. As it is normal glass you will also benefit from the same amount of light as usual, the latter will not be the case with for example, solar shades.

Q - Can mechanical ventilation be retrofitted ?

Answer - Yes, and we assume you refer to Mechanical Ventilation with Heat Recovery (MVHR) although you need to think about the need to fit pipework throughout the property and so you will need to think where you will put that pipework. When retrofitting one tends to use a semi-rigid ducting pipe. They come in 75mm and 90mm diameter, although the 75 mm tends to be preferred for retrofitting. You will need to also think where the main unit will be fitted and then how you will run the pipework from that main unit to all the different spaces within the property. You can, for example, run pipework through a false ceiling or through a stud wall (or build a frame against a solid wall to hide the pipework in). As part of the installation think about the location of the main unit, the pipework versus the insulation within the property (e.g. if your main unit is in a cold roof space, then you need to think about insulating pipework etc.). Please note that the installation of such a unit only really makes sense on a property that achieves a good standard of airtightness, and most properties will require a substantial retrofit anyway to achieve that – hence the requirement for the pipework then becomes part of that retrofit aim. After all, if your property is not airtight then you would not be moving the air within the property but exchanging it with the outside. From a building regulation perspective, you need to choose between trickle vents OR mechanical ventilation with heat recovery.

 

Solar Panels
Q - I already have solar PV panels and mainly use electricity during the day. Should I invest in batteries on top of existing solar PV panels or is it not necessary ?

Answer - That depends on when your main consumption takes place during the day. If you can ensure that your own consumption of electricity mainly falls within the time that your solar PV panels produce electricity, then there is probably not that much benefit in installing batteries – or, in other words, it will take much longer before they payback. So, for example if you are at home during the day and can switch on your main/large consumers (EV, washing machine, dryer, cooking, etc) when you are producing a good output from your solar PV panels, then you would effectively be using the power that your panels are producing. If you go away during the day, for example, to work then your consumption is likely to be low when your panels produce the most (because you are away) and so if you then want to make use of the energy generated by your solar PV panels then a battery system becomes useful. It is also worth looking at what tariff you get for putting your energy onto the grid versus what you will be paying for the electricity if you need to take it from the grid.

Q - Considering all the materials and processes that go into manufacturing solar panels and then decommissioning them, what is better for the environment ? Solar panels or air source heat pumps ?

Answer - This is very much a question around Life Cycle Assessment (LCA) which looks at the full impact of a product from manufacture through to end of life, which was not the focus of our sessions, or our expertise – the additional challenge then often also being that this may be very product (and manufacturer) specific. The key message around changing over to other approaches for heating (or cooling) very much lies in the fact that you should ensure that your property is ready for it and that you have worked on the fabric first. So, ensure that you have considered draught proofing (airtightness) and then also insulating so that your overall demand for space heating has gone down as much as possible. You may then also look at your demand for hot water and ensure that that is not excessive. For example, if you built a passive house, but shower for hours every day, then you will have a high hot water demand, which is something that is not the best for an air/ground source heat pump as they are better at producing an output of 40-45 degrees, but hot water requires going up to 60 degrees Celsius. It is useful to add that recycling for solar PV panels is ramping up, and that they are already very successful at retrieving the precious minerals (which are often only a few grams per panel), and we can expect recycling processes to improve and scale up further as the industry develops. It should be added that the purpose of installing solar panels and/or an air source heat pump may be very different for different homes and that also needs to be considered. While most solar PV panels are installed to generate electricity, an air source heat pump tends to be installed to produce heat (or cooling).

Q - I live in a conservation area and would like to get solar PV panels. How do I make sure I am informed enough to choose the right installer ? For example, I have an old slate roof, how will the panels be fixed to that safely and without damaging/ changing the look ?

Answer - We cannot recommend a specific installer, but ensure that you (learn to) ask the right questions and see how they respond. If you do not get a response at all then they are probably not the right ones – a good installer will want to make sure they do a good job, provide you with the right information and if necessary, get the information required to ensure that you are comfortable with the answer/solution provided – if they do not do this, get wary. So, yes, unfortunately the best way to get to know if that person is just selling you something or knows what they are doing is by making sure you know what it is all about and with a wealth of information available these days you can easily get yourself informed – it is a matter of time, and an investment that will quickly pay off considering the amount of trouble you could avoid getting yourself into. It would also help with respect to ensuring the works happen “to standard” and where necessary have a conversation about that, as you will feel confident to question something as you have the necessary background knowledge.
 As for the fixing systems for solar PV panels. We are not an expert in the different type of systems, but a useful approach is to ask each installer to demonstrate how the system that they use works and how they will ensure that does not damage your roof as such. You should check with your Local Planning Authority if planning permission is required.

Q - Councils offer these "buy together" schemes for e.g. solar PV panels - what are your thoughts on those ? Are the worth it ?

Answer - Group-buying schemes can offer advantages, particularly by making it easier for households to access installers and potentially achieve competitive pricing. However, price should not be the only factor when comparing the options. It is worth comparing quotations on a like-for-like basis, including the specification and quality of the panels, inverter and other components, expected performance, warranties, installer credentials and aftercare. A lower initial price does not necessarily represent better value if the components have shorter warranties, lower performance or a shorter expected lifespan. A useful approach is therefore to compare what is actually being offered rather than simply comparing the headline price. Ask each installer how their proposed system compares with the alternatives and make sure you understand what is included in the price, what warranties apply and who will provide support if something goes wrong. It is also worth remembering that installers will naturally present their own products and systems favourably, so independent comparison of the specifications and warranties can be valuable.

Q - I’m having solar panels installed. We are also replacing our boiler. Can we have both systems to heat our hot water ?

Answer - Yes, if you plan to use solar thermal panels, then you need a storage tank with (at least) two coils. If you use solar photovoltaic panels then you can use the immersion heater to your storage tank to heat the water (and ensure you only switch on the heater when you have sufficient output from your solar panels). Your boiler can then be linked up with the (second) coil to heat the water during the winter in which case it is best to go for a system or heat-only boiler (if possible, with closed system to avoid losing heat via your (non-insulated) loft/storage tank). If you have a tank with two coils, then it is always best to put the solar on the coil lower down in the tank (hot water rises and so you can create more hot water within the tank, while you would then be required to produce less by the boiler which will limit your paid energy consumption).

 

Supply, Demand and Emerging Technologies
Q - In 10 years’ time, can you see the grid coping with private demand (i.e., increased demand from electric vehicle charging points etc) ?

Answer - The grid is in many ways already being stretched. It was originally designed as a hierarchical system where you have the generation/power station at the top and then as you come closer to the user, you reduce the cable width etc. The challenge now is that: 1) there is generation at various different locations, e.g., a farmer who installs a solar farm and starts to produce more power than they ever consumed in the past and then 2) the challenges around an increase in demand due to the electrification of heating and transport, for example. So, overall, the grid is being stretched and investment will be necessary to address these issues. Where possible, it is worth considering greater self-sufficiency to help and ensure you are less affected by any challenges in this area. This is not possible for all properties, but if those that can, do, then that will reduce the demand for those that cannot easily adjust – after all we are all in this together.

Q - Where are we with technology ? Is it worth waiting before investing to get better value when supply exceeds demand ?

Answer - Technology will continue to improve, so waiting indefinitely for the next generation is rarely a useful strategy. There will almost always be something newer, more efficient or more capable just around the corner. A more useful approach is to consider the technology that is available now, its expected lifetime, the cost of installation, the likely improvements offered by waiting and the opportunity cost of delaying the investment. In many cases, the installation and associated work represent a significant part of the total cost, so choosing a well-established and appropriately specified product today may make more sense than waiting several years for a marginally better one. The decision should therefore be based on the specific circumstances: what you need the technology to achieve, how long you expect to use it, what alternatives are available and what you would gain or lose by waiting. As for whether supply will eventually exceed demand and prices will fall, that is much harder to predict and depends on wider market forces rather than technical considerations alone.

 

Water

Q - I would like to know more about grey water harvesting.

Answer - Most people are aware of the harvesting of rainwater using water butts that you link to a down pipe and collect for use in the garden. This is one way of collecting and using grey water. However, if you are planning larger works around your property you may want to consider installing a larger collection tank, which would then be stored underground. These tanks are currently about 5000-7500 litre (in the UK), however, if you look across to the continent then they are typically much bigger (10000-20000 litre). My recommendation is to go as large as you can as if rain becomes more intermittent over time, you will be able to get through a longer dry spell with your storage. What can this water be used for ? Well, most definitely for the garden plants and probably the most important ones here are those in a pot since most of the other plants (including lawns) are much more resilient against drought. Additionally, you may want to consider using it to flush the toilets and possibly for your washing machine (please note that you will need additional/separate pipework to achieve that). Most systems that pump up grey water will have filters on them, and so you should not be getting any “dirty water”. One benefit of grey water lies in the fact that it does not have much limestone within, so tends to be gentler to your washing machine and clothes in comparison to standard tap water.

 

Next Steps

Making A Plan To Suit Your Property
Q - Can you provide me with a process or methodology for assessing our property which includes a logical and effective way forward ?

Answer - It is quite hard to give a “one size fits all” answer to how to approach a property as there may be circumstances that force one in a particular direction, the timeframe available to do something within (like a boiler that just failed) or a desire to replace/improve/upgrade and/or add an extension. If we are to ignore those potential drivers for now, the main or key message and order of approach should probably be quick wins first (where they make sense – see later) and then fabric first. The cheapest energy is the one we do not need, and so we need to ensure that we lower consumption by ensuring that the property is well insulated and airtight. If those are dealt with first, then your heat demand should have gone down, which means you need a smaller air-source heat pump and so on (if you do it the other way around your air-source heat pump may be too large, which can become problematic when your load has lowered). In many cases it is not possible to address the whole property in one go, which is when a room-by-room approach becomes more suitable (for example, if you insulate on the inside) as this reduces impact if you are living within the property. Which rooms you start with could either focus on the rooms you use the most – or the ones that are furthest away from your “entry point for building materials” (after all you probably do not want to be carrying building materials through a freshly redecorated room). So, there is a need for thinking about the larger picture and that starts with reducing demand, but at the same time considering what your end goal is and including that as part of your journey. So, for example you could put in cables/pipework etc for a new heating system that you plan to install when the property has been insulated. Ahead of starting your larger project, there are some quick wins that you can put in place, and they should still be included when you work on the larger project (these are detailed in the presentation and summarized in the additional resources, and include for example, insulating hot water pipes, putting LED lights in, etc).

Q - For privately owned flats, there are limited options around heat pumps and insulation etc. Our flat is located on ground floor, with an EPC D and energy inefficient electric heaters. Since the event, I have thought about getting underfloor heating, but also to get a survey of the property. Any advice on this would be very helpful.

Answer - The challenge with flats often lies around making changes to the outside, however, in many cases you can still make changes to the inside. This can however be more challenging to achieve at times. The appropriate priorities will depend on the construction of the building, the flat's position within it and what alterations are permitted. We would recommend that you have someone come around with a thermal camera, so you understand what the areas of importance are. If your flat is on the ground floor then you are likely to get quite some cold coming from underneath or the floor (unless there is a garage underneath, which could help), and you are likely to lose a lot of your heat to the flat above. So, it may be that insulating the floor/ceiling is going to have a larger impact than insulating the walls. From a heating perspective, if you currently have electric heating then it probably also means that you would be considering electric floor heating, and we do not see much benefit in making that switch. It will not particularly make you feel warm more quickly or make much difference from an energy efficiency perspective. An option you could consider is infrared heating, mounted to the ceiling, as it being a radiant heat you will feel warm more quickly and because it is mounted at the ceiling it will reach the parts of your body that are more sensitive to heat (your upper torso) more quickly. However, you need to consider insulation of floor and ceiling, so you do not suffer from cold feet and/or lose all your heat to the flat above. Heat pumps are another option to consider, and could be combined with, for example, wall heating (the benefit of over floor heating is once again that it reaches your upper torso more easily and so is perceived as warmer more quickly). There is however a need to install the main unit of an air source heat pump outside and that may not be easy. Ground source heat pumps tend to not be an option unless some of the ground is actually yours – or there is a plan to install one for the whole building.

Q - We have a Victorian terraced house, and we know that a lot of work needs doing on drafts, insulation and so on. Where do we start ?

Answer - We would like to refer to the answer for the question "Can you provide me with a process or methodology for assessing ..." (first in this sub-section), as that is pretty much the same question, but for a slightly different property context.

Q - Where can I get advice about making the church net zero? Everyone I ask does not know how to approach this challenge.

Answer - A church is a building, but making it net zero can involve considerations that are quite different from those of a typical domestic or commercial property. Its use patterns, occupancy levels, heating requirements, heritage constraints and the way spaces are used can all have a significant impact on the appropriate approach. The wider system context also matters. A church may be used intensively for short periods but remain largely unoccupied at other times, meaning that simply applying a standard heating or retrofit approach may not be the most effective solution. The starting point should therefore be to understand how the building is used, what constraints apply and where the greatest opportunities for reducing demand lie. There are projects and organisations with experience in improving the energy performance of churches, so it may be useful to look at comparable projects and speak to the local council, heritage bodies and specialist advisers.

Q - I am a landlord and have stopped doing anything to improve energy efficiency of properties as guidance from central government is not clear and, in some cases, disincentivises me from making changes. Where can I look for information about what I need to do ?

Answer - More information on minimum efficiency standards is available on the government webpages.

Q - Fabric First Versus Fabric Fifth, which one to go for ?

Answer - The argument for Fabric First is straightforward: reducing heat loss through insulation and draught-proofing lowers the property's heating demand. This can then reduce the size of the heat pump or other heating system required and may avoid unnecessary changes to radiators or other components. The argument for Fabric Fifth is that installing new technology sooner may deliver benefits more quickly and avoid waiting for a complete retrofit. However, this can also mean installing a larger heating system than ultimately required or making other changes that could have been avoided if the fabric had been addressed first. In practice, the right approach depends on the property and the circumstances. However, where a substantial retrofit is planned, improving the fabric first will often reduce the overall heating demand and make subsequent technology choices simpler and potentially less costly. The key is therefore not to treat Fabric First or Fabric Fifth as universal rules, but to consider the whole system and understand the consequences of the order in which interventions are made.